HOYA TORIC IOL - Diopter: +13.5 D Cylinder: 1.5 D

Product information

  • Quantity Unit Each
  • Product Code None

$819.00 incl GST

Description

The HOYA Vivinex™ Toric Intraocular Lens (IOL) is a specialized lens designed to correct astigmatism during cataract surgery. Crafted from hydrophobic acrylic, this lens offers glistening-free clarity, ensuring long-term visual quality. Its design includes a UV and blue light filter, providing additional protection for the eye.

Optic Design

  • Biconvex, Single-Piece Lens: Features an anterior aspheric surface to partially compensate for corneal spherical aberration, enhancing visual outcomes.
  • Posterior Toric Surface: Aids in precise astigmatism correction.
  • Textured Optic Edge: The square, thin edge design helps reduce posterior capsule opacification.
  • Axis Orientation Marks: Located on the posterior for accurate alignment.

Haptic Design

  • C-Loop Design: Ensures stable positioning within the eye.
  • Textured-Rough Surface: Enhances stability, reducing lens movement post-implantation.

Dimensions

  • Optic Diameter: 6.00 mm
  • Overall Length: 13.00 mm

Power Range

  • Spherical Power: +10.00 D to +30.00 D in 0.50 D increments.
  • Cylinder Power (IOL Plane): 1.00 D to 6.00 D, tailored for precise astigmatism correction.

Injector System

The lens is compatible with the preloaded multiSert™ or Vivinex™ iSert® injector system, facilitating a recommended incision size of 2.20 mm for seamless implantation.

Clinical Performance

  • Rotational Stability: Over 96% of lenses rotate ≤5° post-implantation, ensuring consistent visual outcomes.
  • Reduced Posterior Capsule Opacification: Achieved through active oxygen processing and a smooth lens surface.

Intended Use

Designed for healthcare professionals, the Vivinex™ Toric IOL is intended for adult patients undergoing cataract surgery with pre-existing corneal astigmatism. Its advanced design aims to significantly reduce postoperative refractive astigmatism, enhancing overall visual clarity.

Additional Notes

Clinical studies highlight lower posterior capsule opacification scores and reduced Nd:YAG capsulotomy rates compared to other IOLs, underscoring its effectiveness and reliability. The lens specifications may evolve with ongoing development, maintaining its position at the forefront of intraocular lens technology.

GoSupply