The HOYA Vivinex iSert XC1 CLEAR is an advanced monofocal intraocular lens (IOL) specifically designed for use in cataract surgery. Crafted from glistening-free hydrophobic acrylic, this lens offers exceptional clarity and durability. Its aspheric optic design aims to enhance image quality while reducing visual disturbances, providing patients with improved visual outcomes.

Key Features

  • Material: The lens is constructed from a clear, non-yellow UV-filtered acrylic, ensuring long-term transparency. It contains no metallic components, making it safe for MRI procedures at 1.5 and 3.0 Tesla.

  • Optic Design: The proprietary aspheric optic features a square, thin, and textured edge, designed to minimize dysphotopsia and partially compensate for corneal spherical aberration. This design increases tolerance to optical imperfections such as coma.

  • Haptic Design: The lens includes a textured-rough haptic surface, enhancing grip and reducing adhesion within the capsular bag.

Surface Treatment

The lens undergoes active oxygen processing, resulting in a smooth surface that reduces posterior capsule opacification (PCO). The sharp, square posterior optic edge further acts as a barrier against lens epithelial cell migration, effectively minimizing PCO.

Dimensions and Power

  • Optic Diameter: 6.00 mm
  • Overall Length: 13.00 mm
  • Power Range: Available from +6.00 to +30.00 diopters in 0.50 D increments.

Injector System

The Vivinex iSert preloaded injector system simplifies implantation with a uni-directional slider and screw injector. The front injector tip has an outer diameter of 1.70 mm, suitable for a recommended incision size of 2.0–2.20 mm.

Clinical Performance

The HOYA Vivinex iSert XC1 CLEAR is designed for healthcare professionals aiming to achieve low PCO rates and long-term lens transparency. Clinical studies indicate low Nd:YAG capsulotomy rates, contributing to sustained clarity of vision throughout the patient’s lifetime.

Intended Use

This IOL is intended to provide clear vision and reduce post-surgical complications such as PCO and glistenings. The preloaded system includes specific handling instructions to ensure proper implantation, enhancing surgical outcomes for patients undergoing cataract procedures.