HOYA Vivinex iSert XY1 - Diopter: +25.5 D

Product information

  • Quantity Unit Each
  • Product Code None

$407.40 incl GST

Description

The HOYA Vivinex iSert XY1 is a preloaded intraocular lens (IOL) designed for cataract surgery, crafted by HOYA Corporation. This lens is made from glistening-free hydrophobic acrylic material, featuring integrated UV and blue light filters, ensuring clarity and protection for post-surgical vision.

Optic Design

The lens boasts a proprietary aspheric optic with a biconvex profile, engineered to reduce spherical aberration and minimize coma, particularly in cases of IOL decentration. Its square, thin, and textured optic edge, along with a smooth surface, enhances visual outcomes by maintaining a regular optic surface.

Haptic Design

The haptic design includes a textured-rough surface made from the same acrylic material, providing improved grip and reduced adhesion. This design contributes to the lens's high rotational stability, with clinical studies showing a median rotation of just 1.1°.

Surface Treatment

Active oxygen processing on the posterior surface significantly lowers the incidence of posterior capsule opacification (PCO). The lens's square optic edge further reduces PCO, leading to lower Nd:YAG capsulotomy rates compared to other models like AcrySof IQ SN60WF.

Preloaded Injector System

The Vivinex iSert® injector system simplifies the implantation process with a uni-directional slider and screw injector. The system's front injector tip has an outer diameter of 1.70 mm, suitable for a recommended incision size of 2.20 mm, facilitating a smooth surgical procedure.

Specifications

  • Optic Diameter: 6.00 mm
  • Overall Length: 13.00 mm
  • Power Range: +6.00 to +30.00 diopters (in 0.50 D increments)
  • Nominal A-Constant: 118.9

Image Quality

The aspheric optic design enhances image quality by compensating for corneal spherical aberration and tolerating coma, even with IOL decentration. This results in superior visual performance for patients.

Handling and Use

Intended for use by healthcare professionals, the lens is implanted during cataract surgery. The handling process involves infusing an ophthalmic viscosurgical device, removing the cover, advancing the slider, and injecting the lens through a small incision using the preloaded system.

Additional Information

Design and specifications are subject to change due to ongoing technical development. Vivinex and iSert are trademarks of HOYA Corporation or its affiliates. For comprehensive product details, including indications and contraindications, refer to the Instructions For Use.