TROP-T TEST - Pack Size: 5 Sensitivity: SENSITIVE

Product information

  • Quantity Unit Packet
  • Contains 5 Single
  • Product Code None

Sorry. This item is out of stock

Description

The TROP-T TEST is an advanced in vitro diagnostic tool designed for the precise detection of cardiac troponin T (cTnT) levels in human blood. This assay plays a crucial role in the medical field by aiding in the diagnosis of myocardial infarction and the assessment of acute coronary syndrome (ACS). Its ability to provide early identification of myocardial injury makes it invaluable in emergency rooms, hospitals, and other point-of-care settings.

Key Features

  • High Sensitivity: The test employs high-sensitivity chemiluminescence immunoassay (CLIA) and other immunoassay formats, allowing for accurate detection even at low troponin levels. This sensitivity is essential for early detection of cardiac events.

  • Rapid Results: Depending on the format, results can be available within 12 to 15 minutes for point-of-care assays, or within 1 to 2 hours for high-sensitivity laboratory assays. This quick turnaround supports timely clinical decision-making.

  • Versatile Formats: Available in both quantitative and qualitative formats, the TROP-T TEST can be conducted using serum, plasma, or whole blood samples. The sample volume required ranges from 50 to 150 µL, depending on the assay type.

Test Procedure

The test utilizes monoclonal antibodies specific to cardiac troponin T, providing reliable results through chemiluminescence, optical, or visual detection methods. For laboratory-based assays, compatible analyzers such as ECL100, ECL25, or cobas h 232 are required. The rapid test format, however, offers a visual readout that does not necessitate any instrumentation, making it accessible without specialized training.

Storage and Handling

Proper storage conditions are vital for maintaining the integrity of the test components. Kits should be stored at 2–8°C, with some rapid test formats allowing room temperature storage after opening. Awareness of potential interfering substances, such as biotin, is important to ensure accurate results.

Clinical Application

Healthcare providers are advised to use the TROP-T TEST results in conjunction with other clinical findings, as it is not intended to be the sole basis for diagnosis or patient management. The test is not recommended for screening asymptomatic individuals or for serial monitoring outside hospital environments.

Conclusion

With its robust design and reliable performance, the TROP-T TEST is a critical asset for healthcare professionals in diagnosing and managing cardiac conditions. Adherence to manufacturer instructions and proper sample handling are essential to achieving accurate and meaningful results.

GoSupply

Unit 9/15-17 Gartmore Ave Bankstown NSW 2200

info@gosupply.com.au

1800 299 962

Mon-Fri 9am - 5pm AEDT

GoSupply PTY LTD, ABN: 51 660 241 903